TM 5-2410-233-23
RADIATOR FILLER CAP AND RELIEF VALVE REPLACEMENT - CONTINUED
0062 00
RELIEF VALVE REMOVAL
1.
Remove five capscrews (3), washers (4) and access
3
cover (5).
4
2.
Remove flow control thermostat (6).
5
3.
Remove two gaskets (7) with plate (8). Discard
gaskets.
6
4.
Remove strainer (9).
7
RELIEF VALVE INSTALLATION
8
1.
Install strainer (9).
7
1.
Install two new gaskets (7) with plate (8).
2.
Install flow control thermostat (6).
9
3.
Install access cover (5).
4.
Install five washers (4) and capscrews (3).
386-141
5.
Pressure test radiator as needed to verify cooling system has no leaks and to verify operation of relief valve (WP 0061
6.
Start engine and check for coolant leaks (TM 5-2410-233-10).
END OF WORK PACKAGE