TM 5-2410-233-23
GOVERNOR CONTROLS AND LINKAGE MAINTENANCE - CONTINUED
0054 00
REMOVAL - CONTINUED
15.
Loosen jam nuts (49 and 50) at each end of rod (51).
16.
Remove nut (52), lockwasher (53) and ball joint (54) from bellcrank (34). Remove upper end of rod (51). Discard
lockwasher.
17.
Remove cotter pin (55), washer (56) and pin (57) from clevis (58). Remove lower end of rod (51) from governor control
link (59). Discard cotter pin
18.
Remove spring (60) from lower end of governor control link (59) and from plate (61).
19.
Remove cotter pin (62), washer (63), plate (61), washer (64) and rod end connector (65) from lever (66). Discard cotter
pin.
NOTE
If lever or component inside of a lever requires removal, drive small chisel into slot in lever to open it up for
removal.
20.
If lever (66) requires removal, remove nut (67), capscrew (68), lever and key (69) from support (70)
21.
Loosen jam nut (71) and remove cotter pin (72), washer (73) and pin (74) from clevis (75). Remove lower end of
governor control link (59). Discard cotter pin.
22.
If governor control lever (76) requires removal, remove nut (77), capscrew (78) and governor control lever from
governor.