TM 5-2410-233-23
FUEL TANK ASSEMBLY MAINTENANCE - CONTINUED
0049 00
FILLER CAP, GAGE ROD AND STRAINER CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low
toxic material. However, it may be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open flames and other sources of igni-
tion.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may result in injury or death. Make sure air stream is directed away from user
and other personnel in the area. To prevent injury, user must wear protective goggles or face
shield.
1.
Clean filler cap components and strainer in solvent cleaning compound.
2.
Use compressed air to dry components.
3.
Inspect components for cracks, corrosion, wear or other damage. Replace any damaged component.
FILLER CAP, GAGE ROD AND STRAINER ASSEMBLY
1.
Install gage rod (8) and strainer (9) in fuel tank (10).
2.
Assemble filler cap (1) as follows:
a. Apply a light coat of oil to filter element (7).
b. Install filter element (7) into filler cap (1).
c. Install new gasket (6), baffle (5), new gasket (4), washer (3) and screw (2).
3.
Install filler cap (1) to fuel tank (10) and tighten (TM 5-2410-233-10).
0049 00-3
|