TM 5-2410-233-23
AIR CLEANER FILTER ELEMENTS REPLACEMENT - CONTINUED
0042 00
CLEANING AND INSPECTION - CONTINUED
CAUTION
To prevent primary filter element damage, use a maximum of 40 psi (276 kPa) water pressure.
5.
Direct water inside primary filter element, along length of filter pleats.
6.
Direct water outside along length of pleats. Rinse and air dry primary filter element thoroughly.
7.
Wash primary filter element in warm water and non-sudsing household detergent.
8.
Rinse with clean water and air dry thoroughly.
INSTALLATION
CAUTION
DO NOT attempt to reuse secondary filter element by cleaning.
NOTE
Primary filter element should be replaced once each year or after being cleaned a maximum
of 6 times.
If indicator shows RED shortly after installation of primary filter element, which has been
cleaned approximately 6 times, replace with another clean primary filter element.
If indicator still shows RED shortly after installation of clean primary filter element, change
secondary filter element.
Replace secondary filter element if damaged or after every third primary filter element
replacement.
1.
Install secondary filter element (7) on eight studs inside air cleaner housing (3).
2.
Install eight nuts (6) on studs to secure secondary filter element (7). Tighten nuts to 27 lb-ft (37 Nm).
3.
Install primary filter element (5) in air cleaner housing (3).
4.
If removed, install new gasket (4) in cover (2). Position cover on air cleaner housing (3).
2
4
7
5
6
3
3
386-298
386-297
0042 00-4
|