TM 5-2410-233-23
AIR CLEANER FILTER ELEMENTS REPLACEMENT - CONTINUED
0042 00
REMOVAL
WARNING
If NBC exposure is suspected, personnel wearing protective equipment should handle all air cleaner media.
Consult your NBC Officer or NBC NCO for appropriate handling or disposal procedures.
NBC contaminated filters must be handled using adequate precautions and must be disposed of by trained
personnel.
Failure to follow this warning may cause injury or death.
CAUTION
Never service air cleaner with engine running. Engine damage could result if service is performed with
engine running.
1.
Loosen two eye bolts (1) and remove cover (2) from air cleaner housing (3).
1
2
1
3
386-296
2.
Inspect gasket (4) on inside of cap assembly (2).
4
2
5
Remove and discard gasket only if damaged.
3.
Remove primary filter element (5) from air cleaner
housing (3).
4.
Use a lint-free rag to thoroughly clean inside of air
cleaner housing (3).
3
386-297