TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. Connect
meter
lead
6.
Solenoid and Starting Motor Operate;
directly across battery
Engine Cranks Slowly - Continued.
terminals as shown below.
c. Push governor control 1. If voltage is not 20 volts or
more, go to Table 6,
lever forward past detent
Malfunction 2.
and crank engine for
approximately 30 seconds.
Observe meter reading
after cranking has stopped.
2. If voltage is satisfactory,
replace starting motor (WP
386-497
0006 00-41
|