Click here to make tpub.com your Home Page

Page Title: Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-233-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
6
Before
ROPS
Inspect for loose mounting bolts and ROPS and pads have loose
cracks, bends or broken welds in or missing bolts or cracks,
ROPS and pads.
bends or broken welds.
ROPS
PAD
386-711
REAR AND
RIGHT
SIDE
NOTE
Notify Unit Maintenance to check final drive oil level if Class
III leaks are noted from final drive.
Overall View a. Check on ground under tractor for Class III leaks are evident.
7
Before
evidence of transmission and final
drive oil leakage. Be alert for leaks
from final drive check level/fill and
drain plugs.
b. Check tractor for obvious damage Damage that would impair
that would impair operation.
operation is evident.
0012 00-6

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business