TM 5-2410-233-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
4
c. Note color of coolant. Coolant
(Con't)
should not appear rusty or brownish.
Notify your supervisor if coolant is
rusty or brownish.
NOTE
If unsure of coolant type in your tractor, notify your supervisor.
Use clean water that is low in scale-forming minerals. Do NOT
use softened water.
d. If level of coolant is low, add a 50/50
mixture of antifreeze (Item 1, WP
level up to correct level.
e. Wipe pressure cap clean with a clean
rag (Item 12, WP 0019 00).
f. Inspect radiator cap for damage to Gasket is missing or damaged.
cap or cap gasket, foreign material
and deposits.
g. Install radiator cap.
NOTE
5
Before
0.2 Hours Engine Oil
Level
To ensure an accurate COLD CHECK reading, engine must be
shut down and cold.
a. Wipe area clean around dipstick and
oil filler tube.
b. Remove dipstick, wipe clean, then
reinsert fully into dipstick tube.
Remove dipstick and take reading.
c. Level must be within cross-hatched
area on side of dipstick labeled
SAFE STARTING RANGE WITH
ENGINE STOPPED AND OIL
COLD.
d. If required, add lubricating oil (Item
8, 9, 10 or 11, WP 0019 00). Refer to
correct grade of oil for expected
temperature range.
0012 00-4
|