Click here to make tpub.com your Home Page

Page Title: START ENGINE
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-233-10
OPERATION UNDER USUAL CONDITIONS - CONTINUED
0005 00
START ENGINE
WARNING
DO NOT start tractor engine in enclosed areas without adequate ventilation. Failure to follow this warning
may result in permanent brain damage or death due to carbon monoxide poisoning.
Your hearing can be permanently damaged if you are exposed to constant high noise levels of 85 DB or
greater. Hearing protection is required when operating machine or when working on machine while it is
operating. Failure to wear hearing protection may result in hearing loss.
NOTE
Follow this procedure to start engine at any temperature.
Tractors with ether starting aid system use ether to start engines at temperatures below 32F (0C).
If your tractor is equipped with glow plugs, use glow plugs to preheat precombustion chambers at
temperatures from 60F (16C) to 0F (-18C).
Before attempting to start engine in extreme cold, refer to instructions in WP 0006 00 to prepare tractor for
operation in extreme cold.
1.
Ensure brake lock lever is engaged.
2.
Ensure transmission is in neutral (N) with safety lock lever in ON position.
3.
Ensure all implements are lowered and control levers are in HOLD.
4.
Ensure all accessories are off.
5.
Turn battery disconnect switch to ON.
6.
Pull governor control lever all the way back past detent position, then push forward to 1/3 throttle position.
NOTE
Perform steps 7 and 8 if machine is equipped with a D333 or early model 3306 engine that has glow plugs.
7.
If temperature is below 60F (16C), push in and turn heat start switch to HEAT, for time specified below:
a.
From 32-60F (0-16C), place heat start switch to HEAT for one (1) minute.
b.
From 0-32F (-18-16C), place heat start switch to HEAT for two (2) minutes.
c.
Below 0F (-18C), place heat start switch to HEAT for three (3) minutes.
8.
Release heat start switch when preheat time has elapsed.
NOTE
Perform step 9 if machine is equipped with a later model 3306 engine with an ether starting aid system.
9.
If temperature is 32F (0C) or below, push in and turn heat start switch to START (HEAT START on data plate). Hold
switch in START position while at the same time injecting ether with ether starting aid switch. Push ether starting aid
switch for 2-3 seconds, then release. Proceed to step 10.
0005 00-2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business