2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
10. FAULT CODE 053, 054, 055 OR 056: FLAME CUTOUT IN BOOST
MODE, FLAME CUTOUT IN HIGH MODE, FLAME CUTOUT IN MEDIUM
MODE OR FLAME CUTOUT IN LOW MODE.
INITIAL SETUP
References
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's: Automotive
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
The following steps should only be used if troubleshooting was started at First Chart
For Diagnosis of Arctic Heater Troubleshooting procedure (Para 2-17.1 Fault 1) (all
conditions) and you were referred here.
START
1.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
Fuel level OK (checked at
on Page 2-766.69
STE/ICE #91.
operational level).
Arctic heater intake port
REASON FOR QUESTION
checks OK at unit level.
Arctic heater exhaust port and
If resistance reading is be-
exhaust tube checks OK at
Is resistance across arctic
tween 900 and 1100 ohms at
unit level.
heater flame sensor between
room temperature, arctic heater
Arctic heater fuel lines check
blower may be faulty. If not,
900 and 1100 ohms, at room
OK at unit level.
arctic heater flame sensor is
temperature?
Arctic heater fuel metering
faulty.
pump OK at unit level.
Arctic heater fuel system prime
check OK at unit level.
Replace arctic
heater flame sen-
POSSIBLE PROBLEMS
sor (Para 18-2.2).
NO
Verify repair, go to
Arctic heater flame sensor
Step 2 of this
faulty.
Fault.
Arctic heater control unit faulty.
YES
Replace arctic
heater blower
(Para 18-2.2).
Verify repair, go to
Step 2 of this
Fault.
2-684