Page Title: FAULT CODE 050 OR 052: TOO MANY NO START ATTEMPTS OR NO START SAFETY TIME EXCEEDED. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical circuits, a direct short
may result. Damage to equipment, injury or death to personnel may occur.
NOTE
Refer to arctic heater (Model B) troubleshooting (TM 9-2320-364-20) for fault code retrieval device
S
(FCRD) operation.
If arctic heater does not operate, arctic heater may be in lockout mode due to too many start
S
attempts (code 050). Arctic heater lockout mode (code 050) is activated if arctic heater fails to start
after 20 successive start attempts (10 successive start cycles).
An audible whine will be heard after the system check is completed, indicating the blower motor has
S
switched on and the system is operating. Audible clicking may also be heard from the fuel metering
pump if the arctic heater fuel system isn't primed.
Perform Steps (2) through (4) only if fault code retrieval device (FCRD) is available.
S
Perform Steps (5) and (6) only if fault code retrieval device (FCRD) is not available.
S
VISUAL INSPECTION
(1) Ensure vehicle is returned to normal
operating condition.
(2) Install fault code retrieval device
(FCRD) on arctic heater unit
harness diagnostic connector.
(3) Press the D button on fault code
retrieval device (FCRD) to turn arctic
heater ON.
(4) Clear fault code 050.
(5) Press the D button on fault code
retrieval device (FCRD) twice to turn
arctic heater OFF and ON.
(6) Replace arctic heater control unit
(Para 18-2.2) if fault code retrieval
device is not available.
(7) Turn arctic heater ON
(TM 9-2320-364-10).
(8) Observe arctic heater for proper
operation.
(a) If arctic heater operates, perform
Steps (9) and (10) below and go to
Step 4 of this Fault.
(b) If arctic heater does not operate,
fault not corrected. Perform Steps
(9), (10) and (11) below and notify
supervisor.
(9) Turn arctic heater switch OFF
(TM 9-2320-364-10) or press the D
button on fault code retrieval device
(FCRD), if installed.
(10)If installed, remove fault code retrieval
device (FCRD).
(11) Install cover on arctic heater
(TM 9-2320-364-20).
2-8232-57