Click here to make tpub.com your Home Page

Page Title: SELF-RECOVERY WINCH (SRW) DOES NOT OPERATE. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
1. SELF-RECOVERY WINCH (SRW) DOES NOT OPERATE (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Pressure test.
Unit Troubleshooting tasks
Are a
completed.
minimum
REASON FOR QUESTION
Crane and LHS operate.
of 290 psi
If winch control manifold is faulty,
POSSIBLE PROBLEMS
(2000 kPa) measured at
pressure will be present at
multifunction manifold, port
multifunction manifold, port G9
Shuttle valve faulty.
G9 with winch control lever
with lever held in one direction
Winch control manifold faulty.
and will not be present with lever
held in one direction only?
Counterbalance valve faulty.
held in the other direction. If
SRW motor faulty.
multifunction manifold shuttle
valve is faulty, pressure will not
be present at any time.
Go to Step 3 of this
NO
Fault.
YES
Replace winch control
manifold
(Para 16-37).
Verify repair, go to
Step 7 of this Fault.
2-732

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business