Click here to make tpub.com your Home Page

Page Title: BOOM DOES NOT TELESCOPE OUT OR TELESCOPES OUT SLOWLY. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
High pressure hydraulics [oil under 3000 psi (20,685 kPa) pressure] operate this equipment. Refer to
vehicle operator and maintenance manuals for hydraulic oil pressure. Never disconnect any hydraulic
line or fitting without first dropping pressure to zero. Failure to comply may result in injury to personnel.
Fuel and oil are slippery and can cause falls.
To avoid injury, wipe up spilled fuel or oil
with rags.
NOTE
Use a drain pan to catch leaking hydraulic oil.
FLOWMETER TEST
(1) Tag, mark and disconnect two
hoses from telescope cylinder
fitting and tee on side of boom
without OSS box. Discard
preformed packings.
(2) Install plugs with preformed
packings on disconnected hoses.
(3) Install caps with preformed packings
on fitting and tee.
(4) Start engine (TM 9-2320-364-10).
(5) Set WINCH/CRANE switch to
CRANE position.
(6) Set hydraulic selector switch to
CRANE/SRW position.
(7) Set crane POWER switch to
ON position.
(8) Hold TELE control lever in the IN
position.
(a)  If more than 0 gpm (0 lpm) are
measured, perform Steps (9)
through (18) below and replace
telescope cylinder (Para 16-10)
that is not on the OSS side of
the boom.
(b)  If 0 gpm (0 lpm) are measured,
perform Steps (9) through (18)
below and replace telescope
cylinder (Para 16-10) that is on
OSS side of boom.
(9) Set crane POWER switch to
OFF position.
(10) Set hydraulics selector switch to
OFF position.
(11) Turn OFF ENGINE switch.
(12) Remove two plugs from hoses.
Discard preformed packings.
(13) Remove two caps from tee and
adapter. Discard preformed
packings.
(14) Connect hose with preformed
packing to tee.
(15) Connect hose with preformed
packing to fitting.
(16) Disconnect hose from outboard
(taller) elbow above TELE valve.
Discard preformed packing.
(17) Disconnect adapter hoses from
elbow and hose. Discard preformed
packing.
(18) Connect two hoses with preformed
packings to elbows.

Privacy Statement - Press Release - Copyright Information. - Contact Us