Page Title: HOOK ARM DOES NOT LOAD. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
High pressure hydraulics [oil under
3675 psi (25,339 kPa) pressure] operate
this equipment. Refer to vehicle operator
and maintenance manuals for hydraulic oil
pressure. Never disconnect any hydraulic
line or fitting without first dropping
pressure to zero. Failure to comply may
result in injury to personnel.
Fuel and oil are slippery and can cause
falls. To avoid injury, wipe up spilled
fuel or oil with rags.
Do not get under LHS when disconnecting or
connecting connectors and hoses. A hydraulic
malfunction could cause LHS to lower causing
serious injury or death.
FLOWMETER TEST
(1) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(2) Disconnect hose 2882 from middle
frame bulkhead.
(3) Connect adapter hose to hose 2882.
(4) Connect adapter hose to middle
frame bulkhead.
(5) Connect flowmeter IN port to
adapter hose connected to hose
2882.
(6) Connect flowmeter OUT port to
adapter hose connected to middle
frame bulkhead.
(7) Completely open flowmeter load
valve.
(8) Connect quick disconnects.
(9) Start engine (TM 9-2320-364-10).
(10) Set hydraulic selector switch to
MAN HA position.
(11) With the aid of an assistant, observe
flowmeter while holding joystick in
LOAD position.
(a)  If more than 0 gpm (0 lpm) are
present, perform Steps (12)
through (19) below and replace
RH cylinder (Para 17-12).
(b)  If 0 gpm (0 lpm) are present,
fault not corrected. Perform
Steps (12) through (19) below
and notify supervisor.
(12) Set hydraulic selector switch to
OFF position.
(13) Turn OFF ENGINE switch.
(14) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(15) Disconnect flowmeter from two
adapter hoses.
(16) Disconnect adapter hose from
middle frame bulkhead.
(17) Disconnect adapter hose from
hose 2882.
(18) Connect hose 2882 to middle
frame bulkhead.
(19) Connect quick disconnect hose
2917.