Click here to make tpub.com your Home Page

Page Title: INSTALLATION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-363-20-2
FOOT BRAKE VALVE REPLACEMENT (CONT)
INSTALLATION
0.1
APPLY SILICONE GREASE TO SLIDING SURFACES OF FOOT BRAKE VALVE PLUNGER AND ADAPTER
BORE.
1.
INSTALL FOOT BRAKE VALVE (1), NEW GASKET (2) TWO WASHERS (3), AND TWO SCREWS (4) IN
FIREWALL (5).
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe
sealant compound does not enter air lines or fittings. Failure to do so could
result in equipment failure and/or injury to personnel.
Sealant compounds can bum easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open
fire and use in well-ventilated area.  If sealant compound gets on skin or
clothing, wash immediately with soap and water.
2.
COAT THREADS WITH PIPE SEALANT COMPOUND AND INSTALL ELBOW (6), THREE NIPPLES (7), THREE
CHECK VALVES (8), TWO PLUGS (9), THREE ADAPTERS (10), AND NINE ELBOWS (11) IN FOOT BRAKE
VALVE (1).
3.
INSTALL TUBE (12) AND CONNECT 10 TUBES (13) TO FOOT BRAKE VALVE (1).
NOTE
Follow-on Maintenance:
Connect foot brake valve plunger rod to brake pedal (page 4-403).
4-574 Change 3

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business