Click here to make tpub.com your Home Page

Page Title: 0022-13 Check Timing Sensor Calibration (42)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-312-24-2
Troubleshooting Section
Note: If the "PTO Configuration" is programmed to
Engine Response The injector may not operate
"Remote Throttle", the ECM must receive a proper
while the conditions exist. If the problem is in the
signal from the remote accelerator position sensor
common return line, neither injector will operate.
at all times. The remote throttle signal must be
present even when the PTO ON/OFF switch is in the
Troubleshooting:
OFF position.
Perform the following diagnostic procedure:
"Injector Solenoid Circuit - Test"
System Response:
Electronic System Response The ECM returns the
Results:
engine to low idle when the problem is detected.
OK STOP.
Service Tool Display or Lamps Caterpillar
Electronic Technician (ET) will display "0%" and
i01643489
"DIAG" next to "Throttle Position" on the status
0022-13 Check Timing Sensor
screen while the diagnostic code is active.
Engine Response The engine will remain at low
idle while the diagnostic code is active.
SMCS Code: 1912-038
Troubleshooting:
Conditions Which Generate This Code:
The diagnostic code is probably caused by an
The timing has not been calibrated since the ECM
open circuit in the signal circuit for the accelerator
was installed or the calibration is out of specification
pedal position or an open circuit in the 12 volt
by an amount that is greater than the amount that
sensor supply voltage circuit. An abnormal change
is allowed by the ECM.
in the signal frequency can also cause this code.
System Response:
Perform the following diagnostic procedure:
"Remote PTO Accelerator Position Sensor Circuit -
Electronic System Response The ECM uses
Test"
default timing. Timing can be out of specification by
as much as 4 degrees.
Results:
Engine Response The engine may run rough or the
OK STOP.
engine may emit white smoke in the exhaust. There
may not be any noticeable performance effect.
i01638590
Troubleshooting:
0030-13 PTO Throttle Sensor
Perform the following diagnostic procedure: "Engine
Speed/Timing Sensor - Calibrate"
SMCS Code: 1913-524
Results:
Conditions Which Generate This Code:
OK STOP.
The PTO Configuration is a Customer Parameter.
The PTO Configuration is programmed to "Remote
i01638584
Throttle". The duty cycle of the signal for the PTO
0030-08 Invalid PTO Throttle
Accelerator is less than 5 percent or more than 95
percent.
Signal (29)
System Response:
SMCS Code: 1913-038
Electronic System Response The ECM returns the
Conditions Which Generate This Code:
engine to low idle when the problem is detected.
The "PTO Configuration" is a Customer Parameter.
Service Tool Display or Lamps Caterpillar
The "PTO Configuration" is programmed to "Remote
Electronic Technician (ET) will display "0%" and
Throttle". The ECM is not receiving a correct signal
"DIAG" next to "Throttle Position" on the status
for the PTO Accelerator.
screen while the diagnostic code is active.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business