RIPPER ASSEMBLY MAINTENANCE - CONTINUED
0238 00
INSTALLATION - CONTINUED
CAUTION
Wipe area clean around hydraulic hose assemblies and fittings before they are installed, to prevent
contamination and premature failure of hydraulic system.
Utilize line wrenches for installation to avoid damage to fittings.
NOTE
Lightly coat new O-rings with clean oil before installation.
15.
Install two new O-rings (14) on hose assemblies (12).
16.
Connect each of two hose assemblies (12) to tube assemblies (13) on lift cylinder (6) with two flanges (11), four washers
(10) and capscrews (9). Repeat for other lift cylinder.
12
11
14
9
12
10
6
9
10
14 11
1
6
13
387-763
15
0238 00-7