FINAL DRIVE BEARINGS ADJUSTMENT - CONTINUED
0128 00
ADJUSTMENT - CONTINUED
NOTE
If necessary, tighten adjusting nut to install lock in one adjusting nut.
14.
Install lock (10) with capscrew (8) and nut (9).
10
8,9
387-461
15.
Remove the following tools: capscrews, washers, bearing adjusting tool and stand.
WARNING
Exposure to silicone RTV compound may be hazardous to your health. Contact with eyes can cause sever
irritation and burns. Compound can be absorbed into the skin and can cause irritation or skin sensitiza-
tion. Inhalation of vapors can cause respiratory tract irritation; prolonged inhalation can result in al aller-
gic reaction. Vapors are combustible. Do not use near open flame. Wear eye and skin protection and avoid
inhalation of vapors. Use only in a well-ventilated area. FAilure to follow this warning can cause injury or
death.
NOTE
Coat both sides of new gasket with silicone RTV compound.
16.
Position new gasket (7) and cap (6) and install six cap-
1,2
3
screws (4) and new washers (5).
17.
Install guard (3) with six capscrews (1) and new lock-
washers (2).
18.
Lubricate track roller frame outer bearings by filling
retainer cavity with grease (WP 0010 00).
19.
Lower machine to ground (WP 0243 00).
20.
Adjust track (WP 0132 00).
4,5
6,7
387-460
END OF WORK PACKAGE