TORQUE CONVERTER OIL TEMPERATURE GAGE AND
SENDING UNIT REPLACEMENT - CONTINUED
0083 00
INSTALLATION - CONTINUED
3.
Install bracket (12), two washers (11) and nuts (10) to
10
11
12
secure gage (13) to panel.
387-143
14
13
4.
Carefully route sending unit (2) through bottom of dash assembly and into position. Install rubber grommet (9) into dash
assembly.
5.
Place cover (8) into position on top of dash assembly. Install four capscrews (5), washers (6) and new lockwashers (7).
6.
Using two wrenches, hold fitting (1) and install send-
2
1
3
ing unit (2) into torque converter.
7.
Install capscrew (3) and clip (4) to secure sending unit
line.
8.
Install floor plates (WP 0171 00).
9.
Connect battery cables (WP 0101 00).
10.
Run engine and check gage for proper operation.
4
387-137
END OF WORK PACKAGE
0083 00-3