VALVE LIFTERS REPLACEMENT - CONTINUED
0032 00
CLEANING - CONTINUED
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure when
drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components. DO NOT
direct compressed air against human skin. Failure to follow this warning may result in serious injury or
death. Make sure air stream is directed away from user and other personnel in the area. To prevent injury,
user must wear protective goggles or face shield.
2.
Dry thoroughly using low pressure air.
INSPECTION
1.
Inspect valve lifters for damage and corrosion.
Replace valve lifters if needed.
2.
Refer to Table 1 for wear limits and specifications
applicable to valve lifters. If diameter of valve lifter is
not within specified limits, replace valve lifter.
A
387-411
3.
Refer to Table 1 for valve lifter bore specifications. If valve lifter bore in cylinder block is not within limits specified,
engine must be rebuilt.
.
Table 1. Wear Limits and Specifications.
Diameter (dimension "A") of valve lifter (new)
1.3105 in. +/- 0.0005 in. (33.287 mm +/- 0.013 mm)
Bore (dimension "A") in block for valve lifter (new)
1.3145 in. +/- 0.0020 in. (33.388 mm +/- 0.050 mm)
Maximum permissible clearance between lifter and
0.012 in. (0.30 mm)
bore for valve lifter (worn)
0032 00-2