Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13. Lamp(s) Will Not Light - Continued.
c. Disconnect orange wire
from light switch terminal
B.
d. Set
to
appropriate voltage range
e. Connect meter positive
lead  to  disconnected
orange wire and negative
lead to chassis ground.
ORANGE WIRE
EXTERIOR
LIGHT SWITCH
387-892
f. Place battery disconnect
1. If voltage is indicated, go to
switch in ON position and
Table 6, Malfunction 13, Test
observe meter reading.
6.
2. If voltage is not indicated,
replace broken wire(s) to
switch and/or light switch