TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
All Tractor Electrical Systems Inoperative -
f. Place battery disconnect
1. If continuity is not indicated,
Continued.
switch in ON position.
replace battery disconnect
Clean and/or reconnect battery
2.
Check connection of battery
cables and condition of
cables if necessary.
terminals.
Check
that
battery
is
correctly
connected  to  batteries,
starter and chassis ground
3.
Perform Malfunction 3, Test
1.
4.
If STE/ICE is available,
perform TK Mode, NG81.
STARTING SYSTEM
24 VOLTS
AUX
START
STE/ICE
RECEPTACLE
SHUNT
START
STARTER
SW
CIRCUIT
BREAKER
STARTING
387-871
MOTOR
0006 00-32