TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
Engine Will Not Crank - Continued.
b. Connect meter positive
lead to solenoid terminal
BAT and negative lead to
ground strap.
c. Place battery disconnect
switch in the ON position.
Meter should read battery
voltage.
1.
Recharge
batteries
if
d. With meter still connected
voltage reading is low (WP
as above, place exterior
0100 00). Each cell of
light switch to the ON
battery must show 1.6 volts.
position  for  approxi-
mately 15 seconds. Meter
reading should not be
below 18 volts.
2.
Test starting motor. Go to
Malfunction 5.
4.
All Tractor Electrical Systems Inoperative.
1.
Test  battery  disconnect
switch for continuity.
a. Place battery disconnect
switch in OFF position.
b. Disconnect
negative
battery cable from battery.
c. Disconnect cables from
battery disconnect switch
d. Set multimeter to the
appropriate  ohm  (Ω)
e. Connect meter between
battery disconnect switch
terminals.