TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
Engine Will Not Crank.
1.
Inspect batteries.
1. Replace any cracked, leaking,
a. Visually inspect batteries
corroded or broken batteries
for cracks, leaks and
or batteries with loose or
corroded
or
broken
broken terminal posts (WP
terminal posts.
0100 00). Refer to TM 9-
6140-200-14.
2. Clean corroded terminal posts
(TM 9-6140-200-14).
b. Check for loose, broken or
1. Tighten any loose terminal or
worn
terminals
and
cable.
cables.
2. Replace any terminal or cable
that is broken or worn (WP
Fill each cell to fill ring with
c. Check electrolyte level in
each battery cell (TM 9-
distilled water.
6410-200-10).
1. Charge  all  batteries  not
d. Perform specific gravity
meeting requirements and
test (TM 9-6410-200-14).
recheck specific gravity.
Batteries must test 1.240
or greater, temperature
corrected, and each cell in
battery must test within 25
points of the others.
2. If 25 point variation still
exists, battery is defective and
must be replaced (WP 0100
WARNING
Touch terminal connections one at a time; never touch both
terminals at once. Be sure not to be grounded to the
machine when checking. Failure to do so may cause serious
personal injury or death.