HYDRAULIC PUMP REPAIR - CONTINUED
0149 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low
toxic material. However, it may be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open flames and other sources of igni-
tion.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may result in serious injury or death. Make sure air stream is directed away
from user and other personnel in the area. To prevent injury, user must wear protective gog-
gles or face shield.
1.
Thoroughly clean all parts in solvent cleaning compound.
2.
Dry parts thoroughly with compressed air.
NOTE
If any component of pump and housings (with the exception of seals and retainers) is damaged, replace
pump assembly.
3.
Inspect all components for damage or wear IAW instructions in WP 0176 00. Replace defective components.
ASSEMBLY
CAUTION
Ensure all components are kept clean during assembly. Failure to follow this caution could cause contami-
nation of hydraulic system.
NOTE
Prior to assembly, lightly coat all sub-assembly components, new seals and new O-rings with
clean oil.
During assembly, ensure reference marks for end cover, pump and front pump body are in
alignment.
During assembly, all components must be installed in correct direction of pump rotation.
Pump rotation as seen from splined end of shaft is to the left.
1.
Install new large O-ring (35) in front pump housing (3).
2.
Turn front pump housing (3) over and install new felt ring (34) and seal (33) in front pump housing, with spring-loaded
lip toward pump bearing.
3.
Install washer (32), bearing (31) and new retaining ring (30) in front pump housing (3).
4.
Put a piece of 1 in. diameter pipe, 8 in. long, in position against inner race of bearing (31). Use a driver tool, pipe and a
press to install shaft (28).
0149 00-4