Page Title: TRACTOR, WHEELED, 4 X 4 DED SMALL EMPLACEMENT EXCAVATOR (SEE)
Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

LUBRICATION
ORDER
LO 5-2420-224-12
28 JULY 1993
TRACTOR,
WHEELED,  4  X  4  DED  SMALL
EMPLACEMENT
EXCAVATOR  (SEE)
(NSN
(EIC:EDL)
AND
TRACTOR,
WHEELED,
4
X
4
DED
HIGH
MOBILITY
MATERIAL
HANDLER
(HMMH)
(NSN
Reference: TM 5-2420-224-10 and T M
5-2420-224-20
Level  of  maintenance.  The  lowest  level  of
Intervals (on-condition or hard time) and the related
maintenance authorized to lubricate a point is
man-hour times are based on normal operation. The
indicated by one of the following symbols as
man-hour time specified is the time you need to
appropriate:  Operator/Crew
(C),
and
Unit
do the services prescribed for a particular interval.
Maintenance  (0).
On-condition (OC) oil sample intervals shall be
a p p l i e d unless changed by the Army Oil Analysis
Reporting errors and recommending improvements.
Program (AOAP) laboratory. Change the hard time
You can help improve this manual. If you find any
interval if your lubricants are contaminated or if you
m i s t a k e s or if you know of a way to improve the
are
operating
the
equipment
under
adverse
procedures, please let us know. Mail your letter
operating conditions, including longer-than-usual
or
DA
Form
2028
(Recommended
Changes
to
operating hours. The hard time interval may be
Publications
and
Blank
Forms)
direct
to:
extended during periods of low activity. If extended,
Commander, US Army Tank-Automotive Command,
adequate preservation precautions must be taken.
Hard time intervals will be applied in the event AOAP
ATTN: AMSTA-MB, Warren, Ml 48397-5000. A reply
will be furnished to you.
laboratory support is not available.
TOTAL MAN-HOURS
INTERVAL
MAN-HOURS
WARNING
D
0.4
Death or serious injury could result from
M
3.5
repeated  or  prolonged  breathing  or  skin
4.0
Q
contact of drycleaning solvent SD, type II,
4.5
S
P-D-680, Use in well-ventilated area. Do
A
5.0
not use near open flame or in excessive
heat.
Clean fittings before lubricating. Clean parts with
drycleaning solvent (SD), type II or equivalent. Dry
before
lubricating
NOTE
Dotted arrow points indicate lubrication on
both sides of the equipment.
LO