NOTES - CONTINUED:
8. AUTOMATIC TRANSMISSION.
-15F (-26C). If OEA lubricant is required
T r a n s m i s s i o n uses only Type "F"
to meet the temperature ranges prescrib-
A u t o m a t i c Transmission Fluid NSN
ed in the Key, OEA lubricant is to be used
9150-00-843-1636 (1 Gal. can.)
in place of OE/HDO-10 lubricant for all
temperature ranges where OE/HDO-10 is
specified in the Key.
9. DIFFERENTIAL/DROP GEARCASE.
Change oil each 250 hours. After refill,
2. OIL CAN POINTS. Each 250 hours
operate for five minutes, check for leaks
clean and lightly coat hood hinges, latch,
and bring oil level to fill and level plug
pintle hook, carburetor and accelerator
opening:
linkage and all exposed adjusting threads
with OE/HDO.
10. LUBRICANTS. The following is a list
of lubricants with military symbols and
3. ENGINE OIL LEVEL HOT OR COLD
applicable specification numbers
CHECK. Check engine, oil level should
be at high mark on dipstick. Hot engine,
MIL-L-2104
OE/HDO
oil level must be between high and low
MIL-L-2105
GO
marks on dipstick (allow to set 5 minutes
MlL-G-10924
GAA
before checking).
MIL-L-46167
OEA
MIL-B-46176
BFS
4. ENGINE. Oil is to be changed each
P-D-680
(SD), Type II
100 hours. Drain when lubricant is warm.
Type F
C1A2-19582-C
5. ENGINE OIL FILTER. Each 100 hours,
remove filter, clean filter mount, install
new filter. After installing new filter, fill
crankcase, operate engine for 5 minutes,
check housing for leaks, check crankcase
oil level and bring to "FULL" mark.
Copy of this Lubrication Order will remain
6. TRANSMISSION AND TORQUE CON-
with the equipment at all times, instruc-
VERTER. Check level each 10 hours with
tions contained herein are mandatory.
engine running at idle speed, oil at
operating temperature and transmission
By order of the Secretary of the Army:
in neutral. Maintain oil level at "FULL"
mark. Change oil each 500 hours. Fill
JOHN A. WICKHAM, JR.
transmission to "LOW" mark. Run engine
General, United States Army
at idle speed to fill converter and lines.
Chief of Staff
With engine running at idle speed, oil at
operating temperature and transmission
OFFICIAL:
in neutral, add oil to bring oil level to
"FULL" mark. Operate for 5 minutes and
ROBERT M. JOYCE
check for leaks.
Major General, United States Army
The Adjutant General
7. TRANSMISSION OIL FILTER. Each
500 hours, remove filter, clean filter
DISTRIBUTION:
mount and install new filter and seal. Fill
To be distributed in accordance with
transmission to low mark. With engine
running at idle speed, oil at operating
DA Form 12-256, Operator and Organi-
zational maintenance requirements for
temperature and transmission in neutral,
Tractor.
add oil to bring oil level to "FULL" mark.
Operate for 5 minutes and check filter for
leaks.
TA 219950
CARD 5 OF 5
LO 10-3930-633-12